Back to Top

Hi, Guest!

  LOKASI :  Kota Administrasi Jakarta Timur

Bergabung Selama :

BAGIKAN :   

Bagikan :

SYSTEM 913-12 Automated Transdermal Diffusion Cell - LOGAN

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
52 kali

Harga

CALL
Bagikan
:
PT. SPEKTRA SURYA UTAMA - Distributor Alat Laboratorium yang berdiri sejak tahun 1992.
Distributor peralatan Laboratory, Analytical dan Alat Lingkungan serta :
Polarimeter, Saccharomat, Refractometer, Colorimeter, Saccharoflex - SCHMIDT + HAENSCH
Phone : 021-82750620 Mobile : 082211116326 E-mail : sales@ spektrasurya.com

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail SYSTEM 913-12 Automated Transdermal Diffusion Cell - LOGAN

PT. SPEKTRA SURYA UTAMA merupakan distributor alat laboratorium sejak tahun 1992 dan merupakan distributor peralatan, sebagai berikut :

LOGAN SYSTEM 913-12 Automated Transdermal Diffusion Cell Sampling System

Features

  • Takes samples from 12 bubble free cells for up to 20 sampling time points
  • Open air system, no pressure build up during the test, no leak system
  • Syringe pump sampling system accuracy of ±1%
  • Sampling takes place before media replacement to avoid sample dilution
  • Printer for full report

The Logan System 913-12 is designed to save valuable time by delivering precise transdermal samples into HPLC vials or sample tubes automatically. The membrane is mounted between the cell cap (donor) and the cell body (receptor). The membrane is bathed from below by an isotonic saline solution. Temperature is maintained at 32° or 37°C by thermostatically controlled water which enters the lower port of the water jacket surrounding the saline solution chamber and circulates out through the upper port. Water is supplied and removed by two (upper and lower) stainless steel manifolds connected to a constant temperature bath.

Homogenous distribution of temperature in the saline bathing solution is accomplished by the agitating motion of a Teflon-covered magnetic stirring bar, driven by an external magnet mounted on a timing- motor. The cell cap is open to the air, exposing the membrane’s upper surface to ambient conditions. The open cap also allows for a finite dose application of the compound being studied.

The SYP Series Syringe Pump Module withdraws & measures sample volumes from the transdermal diffusion cells at each time interval. Individual samples are dispensed simultaneously into HPLC vials that are stored in the SCR Series Sample Collectors. To avoid sample dilution, the replacement media takes place right after each sampling. The lift plate tilts all Franz cells to allow all the air bubbles to purge out of the cells while doing the media replacement. This will insure that there is no air bubbles under the skin/patch; the tilted plate goes back to the horizontal position once the media replacement is complete and continues the test.

Specifications

FDC-6T Diffusion Cell Drive Console X 2 w/ VTC-300 Heater Circulator

  • Cell positions.........................6
  • Control zones........................2
  • Zone 1.........................1, 2, 3
  • Zone 2..........................4, 5, 6
  • Speed.................................500 RPM at 50 Hz/600 RPM at 60 Hz
  • Stirring...............................Teflon-coated magnetic bar
  • Temperature control................25°C to 45°C ±1°C
  • Heater................................ 700 watt
  • Voltage..............................110V/120V 50/60Hz or 220V/140V 50/60Hz

SYP-6L2B-10ML Syringe Pump X 2

  • High torque motor driven with encoder feedback loop
  • Controls up to (6) 10 ml syringes
  • Syringe accuracy: ±1% for transfer volume more than 1 ml
  • Maximum transfer volume: 10 ml (as per stroke)
  • Minimum transfer volume: .5 ml (as per stroke)
  • 110/220 Volts, 50/60 Hz
  • Size: 15” X 13” X 20”

SCR–DL Sample Collector

  • Tray A: 240 position collection for 16mm DIA sample tubes (150mm max)
  • Tray B: 240 position collection for Agilent/Shimadzu HPLC vials
  • 12 samples per time point, 20 time points.
  • Built-in replacement media reservoir
  • Size: 19” X 22” X 19”

DSC-800 System Controller

  • Controls the drive consoles, the transfer pump and sampler collector
  • Sampling intervals within 4 minutes
  • Touch panel with color display
  • Link up with printer
  • Supply with support rack
  • 110/220 Volts , 50/60 Hz
  • Size: 6” X 6” X 10”

DEAR-0012 Degassing Station (optional)

  • Vacuum 25in-Hg
  • Power 900 watts
  • Manual or PLC control

 

 

Tampilkan Lebih Banyak