The Orton Model RSV Viscometer is designed to measure the viscosities of a molten glass at various temperatures according to the ASTM C-965 Procedure A.
The Model RSV is a rotating spindle viscometer using the constant angular velocity method to measure viscosities at specific temperatures in order to generate a curve of the visco-elastic behavior of a molten glass. This system can also be used for testing according to ASTM C-1276 and ISO 7884/2 guidelines.

A laboratory bench-top system for measuring the viscosity of molten glass as a function of temperature from room temperature to 1600°C.
Operated according to ASTM C-965/A, ASTM C-1276
| Model | RSV-1600 |
| Warranty | 12 Months |
| Test Method | Rotating Spindle |
| Range | 1.5K - 320M cP |
| Atmosphere | Air |
| Temperature Range | RT to 1,600°C |
| Furnace | Tube style with MolyD elements |
| Sample Thermocouple | Type "S |
| Control Thermocouple | Type "S |
| Crucible/Spindle (not Included) | Platinum/Rhodium |
| Size (Crucible) | 74 mm height 68 mm top diameter, 41mm bottom diameter200ml capacity |
| Size (Spindle) | 292 mm length 8.7mm diameter |
| Sample Volume | 125ml +/- 50ml |
| Sample Weight | 400-500 grams |
| Power Requirements | 20/-240vac/ 20amp, 50 or 60Hz |
| Power Control | 4-20ma / SCR |
| Pedestal | 1650C IFB |
| Pedestal Movement | Vertical, Motor driven lead-screw |
| Temperature Control | Honeywell UDC 3200 Process controller |
| Calibration Sample | 100000cps Fluid (for Room Temp calibration) |
| SRM Calibration Sample | Optional |
| Computer Interface Software | Optional |
| Purge Gas Atmosphere | Optional |
| Bench-top FootprintLength x Depth x Height | 16 x 16 x 58 (41 x 41 x 147 cm) |

A laboratory bench-top system for measuring the viscosity of molten glass as a function of temperature from room temperature to 1700°C.
Operated according to ASTM C-965/A, ASTM C-1276
| Model | RSV-1700 |
| Warranty | 12 Months |
| Test Method | Rotating Spindle |
| Range | 1.5K - 320M cP |
| Atmosphere | Air |
| Temperature Range | RT to 1,700°C |
| Furnace | Tube style with MolyD elements |
| Sample Thermocouple | Type "B |
| Control Thermocouple | Type "B |
| Crucible/Spindle (not Included) | Platinum/Rhodium |
| Size (Crucible) | 74 mm height 68 mm top diameter, 41mm bottom diameter200ml capacity |
| Size (Spindle) | 292 mm length 8.7mm diameter |
| Sample Volume | 125ml +/- 50ml |
| Sample Weight | 400-500 grams |
| Power Requirements | 20/-240vac/ 30amp, 50 or 60Hz |
| Power Control | 4-20ma / SCR |
| Pedestal | 1650C IFB |
| Pedestal Movement | Vertical, Motor driven lead-screw |
| Temperature Control | Honeywell UDC 3200 Process controller |
| Calibration Sample | 100000cps Fluid (for Room Temp calibration) |
| SRM Calibration Sample | Optional |
| Computer Interface Software | Optional |
| Purge Gas Atmosphere | Optional |
| Bench-top FootprintLength x Depth x Height | 16 x 16 x 58 (41 x 41 x 147 cm) |